Edge Impulse Experts / PM_ST4 Public
Data collected
1h 0m 0s
Dataset split
80% / 20%

Dataset

Apply filters

ID Sample name Label Added Length Device Signature Created Sensors
3063747779 ei_pm_station4_diffuser_assembly.s3273 fault_pressure_drop, fault_vacuum_fail 800ms HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747777 ei_pm_station4_diffuser_assembly.s3270 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747775 ei_pm_station4_diffuser_assembly.s3272 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747773 ei_pm_station4_diffuser_assembly.s3271 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747769 ei_pm_station4_diffuser_assembly.s3269 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747767 ei_pm_station4_diffuser_assembly.s3267 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747765 ei_pm_station4_diffuser_assembly.s3266 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747763 ei_pm_station4_diffuser_assembly.s3265 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747759 ei_pm_station4_diffuser_assembly.s3264 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747757 ei_pm_station4_diffuser_assembly.s3262 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747755 ei_pm_station4_diffuser_assembly.s3260 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747753 ei_pm_station4_diffuser_assembly.s3261 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
Raw data

Click on a sample to load...

Metadata

No metadata.