Edge Impulse Experts / PM_ST4 Public
Data collected
1h 0m 0s
Dataset split
80% / 20%

Dataset

Apply filters

ID Sample name Label Added Length Device Signature Created Sensors
3063747771 ei_pm_station4_diffuser_assembly.s3268 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747761 ei_pm_station4_diffuser_assembly.s3263 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747751 ei_pm_station4_diffuser_assembly.s3257 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747741 ei_pm_station4_diffuser_assembly.s3253 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747731 ei_pm_station4_diffuser_assembly.s3247 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747721 ei_pm_station4_diffuser_assembly.s3243 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747711 ei_pm_station4_diffuser_assembly.s3240 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747701 ei_pm_station4_diffuser_assembly.s3233 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747691 ei_pm_station4_diffuser_assembly.s3228 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747681 ei_pm_station4_diffuser_assembly.s3225 fault_pressure_drop, fault_vacuum_fail 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747671 ei_pm_station4_diffuser_assembly.s3218 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
3063747661 ei_pm_station4_diffuser_assembly.s3214 fault_vacuum_fail, fault_pressure_drop 1s HS256 diffuser_press_force_n, pneumatic_pressure_bar, vacuum_pressure_mbar, dispenser_flow_ml_s, press_vibration_g @ 10Hz
Raw data

Click on a sample to load...

Metadata

No metadata.