Manivannan / Pipe Leakage detection Public

Test data

Set the 'expected outcome' for each sample to the desired outcome to automatically score the impulse.
Sample name Expected outcome Length Accuracy Result
water flow - normal.364dr4r5 water flow - normal 32s 100% 60 water flow - normal
Idle.364e13kj Idle 16s 100% 29 Idle
water flow - leakage.364dm39i.s2 water flow - leakage 5s 100% 7 water flow - leakage
water flow - leakage.364dm39i.s6 water flow - leakage 3s 100% 3 water flow - leakage

Model testing output

Model testing results