Manivannan / Pipe Leakage detection Public
Set the 'expected outcome' for each sample to the desired outcome to automatically score the impulse.
Sample name Expected outcome Length Accuracy Result
water flow - normal.364dr4r5 water flow - normal 32s 100% 60 water flow - normal
Idle.364e13kj Idle 16s 100% 29 Idle
water flow - leakage.364dm39i.s2 water flow - leakage 5s 100% 7 water flow - leakage
water flow - leakage.364dm39i.s6 water flow - leakage 3s 100% 3 water flow - leakage

Model testing output

Results

Model version:
Loading...
Loading...